Open Net Zero logo
Water quality modeling in the dead end sections of drinking water (Supplement)
OwnerUnited State Environmental Protection Agency - view all
Update frequencyunknown
Last updatedabout 1 year ago
Format
Overview

Dead-end sections of drinking water distribution networks are known to be problematic zones in terms of water quality degradation. Extended residence time due to water stagnation leads to rapid reduction of disinfectant residuals allowing the regrowth of microbial pathogens. Water quality models developed so far apply spatial aggregation and temporal averaging techniques for hydraulic parameters by assigning hourly averaged water demands to the main nodes of the network. Although this practice has generally resulted in minimal loss of accuracy for the predicted disinfectant concentrations in main water transmission lines, this is not the case for the peripheries of the distribution network. This study proposes a new approach for simulating disinfectant residuals in dead end pipes while accounting for both spatial and temporal variability in hydraulic and transport parameters. A stochastic demand generator was developed to represent residential water pulses based on a non-homogenous Poisson process. Dispersive solute transport was considered using highly dynamic dispersion rates. A genetic algorithm was used to calibrate the axial hydraulic profile of the dead-end pipe based on the different demand shares of the withdrawal nodes. A parametric sensitivity analysis was done to assess the model performance under variation of different simulation parameters. A group of Monte-Carlo ensembles was carried out to investigate the influence of spatial and temporal variations in flow demands on the simulation accuracy. A set of three correction factors were analytically derived to adjust residence time, dispersion rate and wall demand to overcome simulation error caused by spatial aggregation approximation. The current model results show better agreement with field-measured concentrations of conservative fluoride tracer and free chlorine disinfectant than the simulations of recent advection dispersion reaction models published in the literature. Accuracy of the simulated concentration profiles showed significant dependence on the spatial distribution of the flow demands compared to temporal variation. This dataset is associated with the following publication: Abokifa, A., J. Yang , C. Lo, and P. Biswas. Water Quality Modeling in the Dead End Sections of Drinking Water Distribution Networks. WATER RESEARCH. Elsevier Science Ltd, New York, NY, USA, 18(89): 107-117, (2015).

advection dispersionchlorinecorrection factorsdead end pipegenetic algorithmspatial distributionstochastic demands
Additional Information
KeyValue
dcat_modified2015-12-14
dcat_publisher_nameU.S. EPA Office of Research and Development (ORD)
guidA-h9wf-367
ib1_trust_framework[]
language
Files
  • DOCX
    011aeae3-ff29-431e-9978-cf05dad09e2b
  • PDF
    96e22255-f577-4b79-b9e6-b92449f63065
Share this Dataset
water-quality-modeling-in-the-dead-end-sections-of-drinking-water-supplement
Access and Licensing
Access conditionsAccess control: Unknown
License conditionsLicense: